Cabinets and Air

Treatment Equipment

BSC-CITOSTAT1.X

SAFETY CABINET FOR CYTOSTATICS – Model BSC-CITOSTATX.X

Description
Biological safety cabinet for handling cytostatic and antineoplastic agents.

Description

AIR:

  • Partial air recirculation in accordance with regulations: 30% recirculation and 70% exhaust.
  • The work area maintains laminar flow conditions with ISO 4 air purity (according to UNE EN ISO 14644) or Class 10 (according to Fed. Std. 209).
  • The recirculated air is filtered through a ULPA U15 absolute filter (99.9995% MPPS efficiency) or HEPA H14 filter (99.995% MPPS efficiency), in accordance with UNE EN 1822, and is delivered to the work area at a velocity between 0.25 and 0.50 m/s (in accordance with UNE EN ISO 14644).
  • The air expelled to the outside is filtered through a dedicated ULPA U15 or HEPA H14 absolute filter in accordance with the UNE EN 1822 standard.
  • Protective barrier in the work area with a velocity greater than 0.50 m/s.
  • The cabinet is equipped with 3 FILTRATION STAGES, ULPA U15 or HEPA H14 filters; a fourth carbon filtration stage with a specific HEPA or ULPA filter located beneath the work surface may be added, in accordance with applicable regulations

 

CONSTRUCTION:

  • Work area constructed of AISI 304 stainless steel. Optional: AISI 316L.
  • Sliding front glass panel with alarm position. Raises or lowers manually or electronically. Features an anti-pinch function with obstacle detection during glass closure.
  • The safety opening glass is 5 mm thick with UV protection and anti-reflective coating, with an incline of up to 10° to facilitate the user’s viewing of the samples and provide a full view of the work surface.
  • Glass with a special guide that improves sealing and safety during sliding.
  • Microprocessor-controlled cabinet with updatable FLASH memory and an external display for easy viewing of the cabinet’s control parameters (speeds, flow rates, plenum pressure, exhaust barriers, humidity, temperature, etc.), along with an easy-to-use touchscreen featuring a security PASSWORD for controlling and powering on the unit.
  • Alarms for detecting problems in the air supply system and the negative pressure protection barrier, as well as door openings, via voice alerts and/or visual indicators on the screen.
  • Pre-installation for decontamination with Vaporized Hydrogen Peroxide (VHP)
  • Adjustable white LED lighting and UV-free.
  • Operating voltage 110-220 V, 50/60 Hz. Maximum current consumption 3 A (approx. 450 W).
  • The interior of the cabin includes a UV light; 2 IP 55-rated 110-220-volt electrical outlets for 1,000 W each (total 2,000 W).

 

 

Ask about our computerized model for hardware integration:  BSC-CITOSTAT.INF

  • 1 USB port
  • 1 HDMI port
  • 1 DP Port Internet
  • 1 21.5-inch monitor
  • Keyboard stand
  • Computer stand

 

 

“All information, specifications, dimensions, and electrical data shown in TDI’s commercial documents and data sheets are for guidance only and are not binding; therefore, they are subject to change according to each customer’s needs and provided that applicable regulations permit such changes.”

MODEL BSC-CITOSTAT1.1 BSC-CITOSTAT1.3 BSC-CITOSTAT1.8
Internal dimensions  mm (WxDxH) 910 x 600 x 630 1220 x 600 x 630 1700 x 600 x 630
External dimensions mm (WxDxH) 1087 x 760 x 2100 1380 x 760 x 2100 1800 x 760 x 2100
Tested opening Safety height 200 mm (8″)
Max. Opening 440 mm
Work area height 850 mm
Control system Monitor 7″ Color LCD Touchscreen
Alarm Abnormal airflow speed, ULPA/HEPA filter failure, UV lamp failure, front window at an unsafe height.
Airflow System Airflow Mode 30% air recirculation, 70% outdoor exhaust
Downward air velocity 0.35 m/s ± 0.025 m/s
Barrier velocity > 0.52 m/s ± 0.025 m/s
Air exhaust flow rate 347 m³/h 465 m³/h 636 m³/h
Filtration System ULPA or HEPA filters

(Exhaust and Supply)

UNE EN 1822 ULPA or HEPA filters, 2 pieces, ≥99.9995%, ≥99.995% efficiency at 0.1–0.3 μm, filter life indicator,
Air Purity Classification Class 10 (ISO 14644-1 Class 4)
Cabinet Construction Main Body Cold-rolled steel with antimicrobial powder coating
Work Area 304 stainless steel (Optional AISI 316L)
Front Glass Motorized, double-layered laminated tempered glass ≥ 6mm. UV-resistant.
Electrical System UV lamp 20W x 1 30W x 1 40Wx1
254-nanometer emission for more efficient decontamination, UV life indicator, UV timer.
LED lamp 12Wx2 16Wx2 16Wx2
Maximum power consumption 700W (Does not include power consumption from the power outlet)
Fan power 500W
Voltage AC 220V ±10%, 50/60 Hz; 110 V ±10%, 60 Hz
Lighting ≥1000 lx
Noise Level ≤55 dB(A)
Vibration Performance: Amplitude ≤ 5 µm (rms)
Standard Accessories 1. Dimmable LED lights;  2. Air velocity sensor;  3. ULPA filters;  4. LCD touchscreen; 5. LED lamp x 2;  6. UV lamp x 1; 7. IP55-rated waterproof connectors x 2;  8. Motorized front window; 9. Solenoid valve control; 10. RS485 interface; 11. USB port; 12. Foot switch for front window; 13. Support base.
Optional Accessories 1. LED lighting, UGR rating <16; 2. Gas valve; 3. Vacuum valve; 4. Bar with hooks; 5. HEPA filters; 6. Carbon filter.
Net Weight (kg) 224 263 370
Gross Weight (kg) 320 371 495
Shipping Dimensions mm (WxDxH) 1240 x 910 x 2280 1540 x 910 x 2280 2050 x 910 x 2280
Shipping volume (m³3 ) 2.6 3.2 3.7
Description Part Number
Plenum for dual ULPA or HEPA filtration in the exhaust system, providing extra safety when the unit expels air into the laboratory. Request a quote
Third filtration stage, with an additional activated carbon filter for aerosols / removal of volatile chemical compounds and odors.

Different types of activated carbon.

Request price
Side windows. Request price
Front glass panel with hinges for full opening of the work area, XL height of 750 mm. High End. Request price
Hood-type connection for safe extraction. 00-CAMPA-EXT SEG
Check valve. 79-CAJANTR
1” connector for decontamination with vaporized hydrogen peroxide (VHP) in 316L stainless steel 00-VHP-CSB
Solenoid valve for gas tap, controlled from the cabin panel. 32-GE08150
Taps for gas, vacuum, air… 77-006831, 77-006841
LED light with UGR rating < 16 (UGR – Unified Glare Rating) Request price
CODE DESCRIPTION
440206-BSC-CITOSTAT1.1 C10 Cytostatic Workstation. Model BSC-1100
440206-BSC-CITOSTAT1.3 CITOSTATIC CABINET C10. MOD. BSC-1300
440206-BSC-CITOSTAT1.8 Cytostatic Workstation C10. Model BSC-1800

 

CODE DESCRIPTION OF ACCESSORIES AND OPTIONS
440206-BSC-IIA2-XXXX-HE FRONT GLASS WITH HINGES, FULL OPENING WORK AREA, EXTRA-LONG HEIGHT OF 750MM
00-CAMPA-EXT SEG Fume Hood for Safe Extraction in BSC Biological Safety Cabinets
00-VHP-CSB 1” CONNECTOR FOR DECONTAMINATION WITH VAPORIZED HYDROGEN PEROXIDE – VHP 316L STAINLESS STEEL
79-CAJANTR 4mm THICK METHACRYLATE NON-RETURN BOX, 330mm X 150mm
32-GE08150 GAS SOLENOID VALVE WITH AUTOMATIC RESET, N.C., 230VAC, 1/2″, Pmax 6 bar RP
77-006831 WALL-MOUNTED STRAIGHT GAS TAP (LIGHT GRAY WITH YELLOW KNOB, FOR NATURAL GAS, 125MM THREAD)
77-006841 WALL-MOUNTED STRAIGHT VACUUM VALVE (LIGHT GRAY, FOR VACUUM UP TO 1 mbar, WITH SPECIAL 125MM THREAD)

Ask for information

Ask for more information about:
SAFETY CABINET FOR CYTOSTATICS – Model BSC-CITOSTATX.X

Before submitting the form, you can read the basic information on data protection here:

  • Responsible: TDI Diagnostic and Research Technology.
  • Purpose: Respond to your comment and notify you of new responses.
  • Legitimation: Your consent through this form.
  • Recipients: We do not plan to transfer your data to third parties, except by legal obligation.
  • Rights: You have the right to access, rectify, delete, portability and opposition to your data. The contact information will be stored on our servers.
  • Additional information: You can consult the additional and detailed information on data protection in the link at the bottom of this page.
Description
Biological safety cabinet for handling cytostatic and antineoplastic agents.

Ask for information

Ask for more information about:
SAFETY CABINET FOR CYTOSTATICS – Model BSC-CITOSTATX.X

Before submitting the form, you can read the basic information on data protection here:

  • Responsible: TDI Diagnostic and Research Technology.
  • Purpose: Respond to your comment and notify you of new responses.
  • Legitimation: Your consent through this form.
  • Recipients: We do not plan to transfer your data to third parties, except by legal obligation.
  • Rights: You have the right to access, rectify, delete, portability and opposition to your data. The contact information will be stored on our servers.
  • Additional information: You can consult the additional and detailed information on data protection in the link at the bottom of this page.