VERTICAL FLOW GAS EXHAUST CABINET – FHX Model

Description
Chemical Protection.   The FHX series fume hoods are designed for modular laboratories where safe ventilation is required, minimizing exposure to and inhalation of chemical contaminants.

Description

  • The FHX series fume hoods are designed for modular laboratories where safe ventilation is required, minimizing exposure to and inhalation of chemical contaminants.
  • It is constructed of epoxy-coated steel. The side panels are made of glass. The front panel is angled at 10° for user comfort. The front glass panel slides open via a motor.
  • The work surface is removable for easy cleaning and is constructed of materials highly resistant to chemicals.
  • Manually sliding front glass panel.
  • Protective barrier in the work area with a flow velocity greater than 0.5 m/s.
  • Standard units come equipped with special activated carbon filters, and absolute filters can be optionally installed, depending on the contaminants to be retained. A tube up to 4 meters long can be connected to the outlet and extended to the outside without the need for a booster fan.
  • Standard units are equipped with a water connection and drain, a gas connection, and two 220 V outlets.
  • Microprocessor-controlled cabinet for adjusting the speed.
  • The cabinet is equipped with an easy-to-use touch panel for controlling white/ultraviolet lighting, an internal power outlet, a gas valve, and parameters.
  • Fluorescent and UV lighting.
  • Operating voltage 220 V / 50 Hz. Optional 110 V / 60 Hz. Maximum current consumption 6 A (approx. 1300 W).
  • The cabinet comes standard with a UV light; 1 IP55 electrical outlet for 1000 W loads, water inlet, gas inlet, sink, and support table.

 

“All information, specifications, dimensions, and electrical data shown in TDI’s sales materials and data sheets are for reference only and are not binding; therefore, they are subject to change based on each customer’s needs and provided that applicable regulations permit such changes.”

MODEL FHX 1000 FHX 1200 FHX 1500 FHX-1800
Interior Dimensions (mm) 880 x 730 x 745 1100 x 730 x 745 1405 x 730 x 745 1710 x 730 x 745
External Dimensions (mm) 1000 x 850 x 2150 1220 x 850 x 2150 1525 x 850 x 2150 1830 x 850 x 2150
Shipping dimensions (mm) 1140 x 1100 x 1635 1360 x 1100 x 1635 1665 x 1100 x 1635 1970 x 1100 x 1635
Work Surface Height 850 mm
Maximum Opening 520 mm
Barrier Speed 0.3   —-   0.8 m/s
Noise Level </= 60 dB
Exit Tube PVC, maximum length 4 meters
Outlet Pipe Diameter 300 mm
Total shipping weight (kg) 250 280 330 390
Cab body material Exterior made of electro-galvanized steel sheets with antimicrobial powder coating
Work surface material Acid- and alkali-resistant physicochemical board
Control system Microprocessor-controlled control panel with upgradeable FLASH memory
LCD touchscreen Control panel with 6-speed settings and light.
OPTIONAL filter HEPA H14 filter with 99.995% efficiency at 0.3µm
Standard accessories 1 x IP55 power outlet (1000W) + 1 water tap + sink + 1 gas tap + support table.
Front glass Tempered glass, 5mm, UV-resistant
LED lighting 1 x 6.5 W 1 x 9.6 W 1 x 9.6 W 1 x 9.6 W
UV light 1 x 20 W 1 x 30 W 1 x 30 W 1 x 30 W
Power consumption 400 W 500 W 500 W 500 W
Power 220 V, 50 Hz ± 10%; 110 V, 60 Hz
Code Description
440206-FHX1000 FHX 1000 Gas Extraction Cabinet
440206-FHX1200 FHX 1200 Fume Hood
440206-FHX 1500 FHX 1500 Fume Hood
440206-FHX1800 FHX 1800 Fume Hood

Ask for information

Ask for more information about:
VERTICAL FLOW GAS EXHAUST CABINET – FHX Model

Before submitting the form, you can read the basic information on data protection here:

  • Responsible: TDI Diagnostic and Research Technology.
  • Purpose: Respond to your comment and notify you of new responses.
  • Legitimation: Your consent through this form.
  • Recipients: We do not plan to transfer your data to third parties, except by legal obligation.
  • Rights: You have the right to access, rectify, delete, portability and opposition to your data. The contact information will be stored on our servers.
  • Additional information: You can consult the additional and detailed information on data protection in the link at the bottom of this page.
Description
Chemical Protection.   The FHX series fume hoods are designed for modular laboratories where safe ventilation is required, minimizing exposure to and inhalation of chemical contaminants.

Ask for information

Ask for more information about:
VERTICAL FLOW GAS EXHAUST CABINET – FHX Model

Before submitting the form, you can read the basic information on data protection here:

  • Responsible: TDI Diagnostic and Research Technology.
  • Purpose: Respond to your comment and notify you of new responses.
  • Legitimation: Your consent through this form.
  • Recipients: We do not plan to transfer your data to third parties, except by legal obligation.
  • Rights: You have the right to access, rectify, delete, portability and opposition to your data. The contact information will be stored on our servers.
  • Additional information: You can consult the additional and detailed information on data protection in the link at the bottom of this page.